Vue de la page 0
Dissolved
Oxygen
Water Quality Test Kit
Instruction Manual
Code 5860-01
Dissolved
Oxygen
Vue de la page 0
1 2 3 4 5 6 ... 19 20

Résumé du contenu

Page 1 - Dissolved

DissolvedOxygenWater Quality Test KitInstruction ManualCode 5860-01DissolvedOxygen

Page 2

10DISSOLVED OXYGENCODE 5860-01QUANTITY CONTENTS CODE30 mL *Manganous Sulfate Solution *4167-G30 mL *Alkaline Potassium Iodide Azide *7166-G30 mL *Sulf

Page 3 - INTRODUCTION

11DISSOLVED OXYGEN TEST PROCEDUREPart 1 - Collecting the Water SampleRinse the Water Sampling Bottle (0688-DO) with the sample water.Tightly cap the b

Page 4 - PERCENT SATURATION & BOD

12DISSOLVED OXYGEN TEST PROCEDUREPart 2 - Adding the ReagentsNOTE: Be careful not to introduce air into the sample while adding the reagents.Remove t

Page 5 - Decomposition

13DISSOLVED OXYGEN TEST PROCEDUREPart 3 - The Titration00.10.20.30.40.50.60.70.80.91.000.10.20.30.40.50.60.70.80.91.000.10.20.30.40.50.60.70.80.91.000

Page 6 - TESTING DISSOLVED OXYGEN

14DISSOLVED OXYGEN TEST PROCEDURE continued ...Insert the tip of the Titraror into the opening of the titration tube cap.Slowly depress the plunger

Page 7

15aAtmospheric Pressure (mmHg) Equivalent Altitude (ft) Correction Factor 775 540 1.02 760 0 1.00745 542 0.98 730 1094 0.96714 1688 0.94699 2274 0.9

Page 8 - GENERAL SAFETY PRECAUTIONS

16BOD1212Collect two samples according to Part 1 – Collecting the Water Sample.Test one sample immediately by following the procedures in Part 2 – Add

Page 9

17EPA COMPLIANCETo qualify as an EPA accepted test, and to achieve the greatest accuracy, the Sodium Thiosulfate Solution, 0.025N (4169) must be stand

Page 10 - Kit Diagram

18EPA COMPLIANCE continued ...Read the test result directly from the scale where the large ring on the Titrator meets the Titrator barrel. Include th

Page 12

Introduction ... 3Dissolved Oxygen ...

Page 13

LaMOTTE COMPANYHelping People Solve Analytical ChallengesPO Box 329 • Chestertown • Maryland • 21620 • USA800-344-3100 • 410-778-3100 (Outside USA) •

Page 14

3INTRODUCTIONAquatic animals need dissolved oxygen to live. Fish, invertebrates, plants, and aerobic bacteria all require oxygen for respiration. Oxyg

Page 15 - PERCENT SATURATION

4DISSOLVED OXYGEN, PERCENT SATURATION & BODOxygen is critical to the survival of aquatic plants and animals, and a shortage of dissolved oxygen is

Page 16

5WHERE DOES THE OXYGEN GO? Once in the water, oxygen is used by the aquatic life. Fish and other

Page 17 - EPA COMPLIANCE

6MEASURING BOD (BIOCHEMICAL OXYGEN DEMAND) Biochemical oxygen demand is determined by measuring the dissolved oxygen concentrat

Page 18 - EPA COMPLIANCE continued

7Simultaneously, iodine from the potassium iodide in the Alkaline Potassium Iodide Azide Solution is oxidized by manganic sulfate, releasing free iodi

Page 19

8 GENERAL SAFETY PRECAUTIONSInstructionManualMaterialSafetyData SheetStore the test kit in a cool dry area.Read all instructions and note precautions

Page 20 - SHORT FORM INSTRUCTIONS

9Use test tube caps or stoppers, not yourfi ngers, to cover tubes during shaking or mixing. Hold dropper bottles vertically upside-down, and no